Before you start to install corrugated metal roofing you need to figure out how much you need.
How to overlap metal corrigated roofs.
Lay the remainder of the row.
Any end laps must be supported by a suitable purlin.
Metal roofing resists rot is not susceptible to insect damage and is non combustible a boon in fire prone areas.
When the panel is laying flat on a surface the side that touches flat is the underlap side.
Sweep the metal roofing sheets of all dirt and debris with a push broom.
Make sure the panel is square to the roof line.
On the eave side of the roof aim to overhang the panels by 1 to 1 5 inches.
If end laps are required you should allow 300mm minimum overlap sealed with butyl sealant tape 10mm from the edge of each overlapping sheet as well as in the middle of the overlap.
Continue onto the next rows.
Place the first screw.
2 corrugated metal roof installation instructions.
One downside is that the metal sheets have a susceptibility to denting both in installation and during hailstorms.
Be sure the larger edge is laid so that the small edge of the next panel will overlap it.
Align the first metal roofing panel so that it overlaps the edging by 1 2 to 3 4 of an inch and is square to the roof.
Lay the roofing felt.
Overlapping anti condensation lined sheets.
Install the roofing screws vertically along each rib in the panel.
A corrugated metal roof is quieter than pvc when it rains.
2 lay 6 inch wide butyl tape over all horizontally lapping end seams.
Complete the first row.
Position the tape with the release backing on the top.
The opposite end the overlap side will be elevated slightly above the surface.
How to install corrugated metal roofing.
Measure the length of the.
Lay and secure the first metal panel.
Fit the first sheet.
When laying the metal panels on the roof the overlap ridge of the new panel should straddle the underlap ridge of the panel before it.