Openings for ventilation having a least dimension of not less than 1 16 inch 1 6 mm and not more than 1 4 inch 6 4 mm shall be permitted.
Ibc attic access size.
For i think the first time in newer construction warranty inspection i came across one with just a little scuttle hatch instead of a attic stair.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
However is a permanent means of access required as in a fixed ladder.
Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that exceed 30 square feet 2 8 m2 and that have a vertical height of 30 inches 762 mm or greater over an area of not less than 30 square feet.
2009 ibc from previous discussions i understand that stairs are not required to attics.
306 3 appliances in attics.
Minimum opening size the 2012 international residential code requires an attic access opening for attics with an area greater than 30 square feet and a vertical height in excess of 30 inches.
The type of attic access determines the means you can install for entrance into the attic.
Is there a requirement for certain size or type access to furnace air handlers in an attic.
Building codes according to the 2006 international residential code r807 1 attic access homes with combustible materials in the ceiling and roof construction must have an access to attic areas that exceeds 30 square feet and with a vertical height of 30 inches or greater.
Openings for ventilation having a least dimension larger.
International residential code 2003 requires any attic area exceeding 30sf in area and that have a vertical height of 30 inches or more.
Thanks from the 2009 imc.
See section m1305 1 3 for access requirements where mechanical equipment is located in attics.
Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that have a vertical height of 30 inches 762 mm or greater over an area of not less than 30 square feet 2 8 m 2 the vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members.
Or is a step ladder code compliant.