Ibc 1203 2 requires 1 150 th of the attic area to be ventilated but there is an exception that is commonly used instead.
Ibc attic definition.
The ibc provides definitions in chapter 2 of terms that are generally used in a number of varied locations throughout the code.
2018 international building code.
Exterior openings into the attic space of any building intended for human occupancy shall be protected to prevent the entry of birds squirrels rodents snakes and other similar creatures.
1 foot 304 8 mm 1 square foot 0 0929 m 2.
Attic or storyfrom the 2006 ibc commentaryattic.
Chapter 15 roof assemblies and rooftop structures of the ibc identifies roof ventilation under section 1503 5 roof ventilation.
Openings for ventilation having a least dimension of not less than 1 16 inch 1 6 mm and not more than 1 4 inch 6 4 mm shall be permitted.
2018 international residential code.
Attic section 202 identifies an attic as that space between the ceiling beams at the top story and the roof rafters.
A code provision sometimes overlooked is in the definitions in chapter 2 of the 2015 ibc.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
The international building code commentary often provides clarification and the intent of code provisions.
See chapter 10 means of egress particularly 1011 12 stairway to roof 1011 12 2 roof access and 1011 16 ladders.
Nonclassified roof coverings shall be permitted on buildings of group r 3 and group u occupancies where there is a minimum fire separation distance of 6.
Exception 1 allows you to only ventilate 1 300 th of the attic area if 50 to 80 of the ventilation occurs at least 3 above eave or cornice vents.
It is the opinion of rci that the lack of such provisions in the 2015 ibc will increase the probability of roof collapses.
This section states that intake and exhaust vents shall be completed in accordance with section 1203 2 of the ibc.
The residential code applies to dwellings not more than three stories above grade plane which is what you have plus what appears to be a habitable attic if you chose to use the space as such.
Chapter 9 roof assemblies.
Section 1203 attic spaces is defined in chapter 12 interior environment.
Unless otherwise required in accordance with the international wildland urban interface code or due to the location of the building within a fire district in accordance with appendix d.
Openings for ventilation having a least dimension larger.
The space between the ceiling beams of the top story and the roof rafters.
On the upcodes website.
The code official is wrong imo.
The habitable attic was added in the 2009 addition in an attempt to gain bonus space above the 3d floor while remaining in the irc.